Emergency Stop Switch
Explanation:
External stop signal.
WARNING! Emergency Stop Switch
See Operator's Manual
Symptom:
Engine stops or can not be started.
Action:
• Check emergency stop button if any. Reset if necessary. Se
Engine Shutdown page 36.
• Please contact a Volvo Penta workshop if the fault remains.
Primary Battery
Explanation:
Poor batteries or charging.
WARNING! Primary Battery See Oper-
ator's Manual
Symptom:
None.
Action:
• Check the batteries fluid level. Se Battery, Mainte-
nance page 80.
• Check belt tension. Se Drive Belt, Check and
Change page 62.
• Please contact a Volvo Penta workshop if the fault remains.
EMS Supply Fuse
Explanation:
The fuse has blown.
WARNING! EMS Supply Fuse See
Operator's Manual
Symptom:
Engine cuts out.
Action:
Please contact a Volvo Penta workshop.
Fault Code Register
50 7748887 04-2008
Comments to this Manuals